• Fire Extinguisher Maintenance Service
t is not everyday that you would use your fire extinguisher and it is easy to forget about their existence. However, it should be in top shape when you need it in a time of emergency. Just like any other device, fire extinguishers need regular maintenance in order to ensure that the device works perfectly. Since a fire extinguisher is extremely important during a fire, and if it doesn't work to its capacity during the hour of crisis, there can be a lot of damage. Therefore it is essential to make sure you follow fire extinguisher maintenance well.
Here are some tips to help you get started. Remember that there are plenty of varieties of fire extinguishers in the market today, catering to different needs of the people. Therefore it is essential that you understand your device well and also read the user manual completely to check everything about maintenance.
On a regular basis, typically twice a year, as per AS1851-2005 get your fire extinguisher serviced through a state or federally authorized agency.
Quick inspections should be carried out periodically to make sure everything is in proper order.
You should make sure that all fire devices and your fire extinguisher are in proper working condition. This can be ensured by having a reputable fire company check your equipment.
Most varieties of chemical fire extinguishers contain a number of chemicals inside the canister. This requires an occasional shaking, because otherwise some heavier chemicals tend to settle down, thereby destroying the homogeneous mixture and this can greatly reduce efficiency. You need to check if your fire extinguisher requires such regular shaking, typically once a month. If so, do not neglect this.
Always check for and ensure easy accessibility to your fire extinguisher by all family members. This is very important because if it isn't accessible in the time of emergency, then there is no use having it in the first place.
Check for leaks, dents, rust and wear and tear. Ensure that seals and pins are unbroken.
• Mechanical Foam (AFFF) Fire Extinguishers
We provide Mechanical Foam (Afff) Fire Extinguishers. Useful for Class 'A' & Class 'B' fires involving flammable liquids such as Naphtha, Paints, Solvents, Tar, Varnish, Benzene Camphor and fats like Grease and Oils, Solids like Resins and Oils, Pigments. Foam extinguish fire by blanketing (Cutting off atmospheric supply of oxygen to the burning surface) and cooling down the container and the contents.
B.I.S. Specification : 10204 : Latest
Capacity : 9 Liters with ISI mark.
Spec.5507 : 50 liters mounted on 2 rubber wheel trolley, Each appliance comes with initial charge.
Type : Upright
• A B C type Fire Extinguishers
We Are Manufacture Of Fire Extinguishers And Also Provide The Service If License Of Fire Extinguishers
Useful for class A, B & C fires involving wood, cotton, flammable liquids, grease, electrical wiring, live machineries etc. The blanketing effect of ABC powder decomposes fire quickly.
B.I.S. Specification: 13849 :Latest
Capacity : 1Kg, 2 Kg, 5 Kg, 10 Kg, & above with ISI Mark
• Co2 Type Fire Extinguishers
Useful for class 'B' & 'C' fires involving materials like Fabric, Oil Spillages and delicate machineries. Co2 extinguishers fire by blanketing dilution of oxygen and cooling effects
B.I.S.
Specification: 2878: Latest
Capacity : 1 to 6.5 kg. & 22.5 kg available with ISI Mark. Appliances of 50/100 lbs capacity mounted on trolley wheels are also available
• Clean Agent type Fire Extinguishers
We provide Clean Agent Type Fire Extinguishers. Useful for class A, B & C fires involving wood, cotton, flammable liquids, grease, electrical wiring, live machineries etc.
Capacity : 1Kg, 2 Kg, 5 Kg, 10 Kg, & above
Type : Cylindrical, Upright
• Automatic Modular Type Fire Extinguishers
Useful for class A, B & C fires involving wood, cotton, flammable liquids, grease, electrical wiring, live machineries etc. The blanketing effect of ABC powder decomposes fire quickly.
Available in 5, 10, 15 Kgs.
• Dry Chemical Powder Fire Extinguishers
Useful for class B & C fires involving Oils, Fats, Solvents, Gases, Paints, Varnish, Electrical Wiring and Live Machineries. Dry chemical powder extinguishes fire by beating, displacement of air and decomposition of dry powder effects
B.I.S. Specification : 2171 :Latest
Capacity : 5kg, 10 kg, 25kg,50 kg,70 kgs with ISI mark
Type : Cylindrical, Upright
• Fire Extinguishers & Refilling of Fire Extinguisher
"A B C" Stored pressure type Dry chemical powder fire extinguishers: This ABC fire extinguisher is useful for fires of class A, B & C types which involve wood, cotton, flammable liquids, grease, electrical wiring, live machineries etc. The blanketing effect of ABC powder decomposes fire quickly.
B.I.S. Specification: 13849
Capacity:1Kg, 2 Kg, 5 Kg, 10 Kg, & above with ISI Mark
CO2 type fire extinguishers: These products are useful for class 'B' & 'C' fires involving materials like fabric, oil spillages and delicate machineries. CO2 extinguishers fire by blanketing dilution of oxygen and cooling effects.
B.I.S. Specification: 2878
Capacity: 2, 3.2, 4.5, 6.5, 9 kg. & 22.5 kg with ISI Mark
Trolley mounted Dry chemical powder type fire extinguishers: These are useful for class B & C fires involving Oils, Fats, Solvents, Gases, Paints, Varnish, Electrical Wiring and Live Machineries. Dry chemical powder extinguishes fire by beating, displacement of air and decomposition of dry powder effects.
B.I.S. Specification: 2171 & 10658 :
Capacity: 5kg, 10 kg, 25kg,50 kg,75 kgs with ISI mark
Mechanical foam (AFFF) type fire extinguishers:These are used for Class 'A' & Class 'B' fires involving flammable liquids such as Naphtha, Paints, Solvents, Tar, Varnish, Benzene Camphor and fats like Grease and Oils, Solids like Resins and Oils, Pigments. Foam extinguisher controls fire by blanketing (Cutting off atmospheric supply of oxygen to the burning surface) and cooling down the container and the contents.
B.I.S.
Specification: 10204 & 13386 :
Capacity: 9 ltr & 50 ltr with ISI mark
Clean Agent Fire Extinguishers
• Fire Extinguishers and Refilling
All types of fire extinguishers & refilling of fire extinguishers
• Water Co2 type Fire Extinguishers
Useful for Class 'A' fires involving ordinary carbonaceous materials such as Wood, Paper, Cotton, Jute etc. Water CO2 type extinguishers fire by cooling and quenching effects
B.I.S. Specification : 940 : Latest
Capacity : 9 Liters & 50 Liters duly mounted on 2 wheel rubber trolley with ISI mark
Type : Cylindrical
CAUTION : NOT FOR USE ON OIL AND ELECTRICAL FIRE