Universal Counters
Specifications of Universal Counters:
- Display : 16 x 2 line LCD display.
- No. of digits : Maximum 8 Digits.
- Maximum Speed of count : 200 counts / Sec.
- Minimum pulse width of pulse : 1 mesc.
- Counting Method : Up counting.
- Control O/P. : 1 c/o relay contact rated at 3A/230 VAC
- Settings : All setting by keyboard.
Input Pulse:
- 230 VAC/110 VAC pulse through contactor or limit switch.
- 10-30V DC Proximity switches three wires PNP-NO-type.
- Any 10-30 VDC pulse.
Reset Methods:
- Manual reset by key-always valid.
- Auto reset – If selected, Auto reset time programmable by keyboard.
- Power on reset, if selected count will reset to all zero at power on & count will start from zero.
- Power on reset & auto reset – if selected, combination of B & C.
Count Display:
- Set value : 8 digits.
- Actual value : 8 digits.
- Total Count : 8 digits
- Batch Count : 4 digits.
- Count Memory : count memory for a) Actual Count
- Total Count and Batch Count
- Terminations : All terminations for supply, relay, pulse input etc. at back of unit.
- Keyboard : All setting & display page change through keyboards only.
- Power : 230 VAC /- 10%, 50 Hz, Single Phase or 24VDC
- Size : a) Overall : 96 x 96 x 120 mm
- Cut Out : 90 x 90 mm
- Options : a) External Reset - By 230V AC Pulse or 24VDC Pulse
- Extra Alarm Output - one N.O.C. relay contact for additional alarm O/P.