Calibration Gas Instrument
Cal 2000 Calibration Gas Instrument
- Our most flexible and accurate instrument.
- The only source for chlorine dioxide calibration gas.
- Mass flow feedback provides sample draw calibration capabilities up to 5 lpm.
- 50 and 100 hour sources available.
- English, French, German and Spanish user interfaces are available.
- CSA certified and intrinsically safe.
Accurate Calibration Gas Generation
The Cal 2000 provides unmatched versatility and accuracy in calibration gases. Field replaceable calibration gas sources (generating cells) provide a calibration standard for accurately testing Chlorine, Chlorine Dioxide, Hydrogen, Hydrogen Cyanide, and Hydrogen Sulfide gas detectors with a single instrument.
Cal Gas at a Fraction of the Cost
The Cal 2000 is microprocessor controlled, and has an LCD display allowing field adjustable gas concentrations and flow rates. The sources are interchangeable and field replaceable. Best of all, the Cal 2000 provides up to 100 times as much calibration gas as a disposable cylinder at a fraction of the cost. The electrochemical generating cells do not degrade over time.
Extreme Flexibility
The Cal 2000 instrument has a built-in mass flow sensor that automatically compensates for altitude and temperature. The mass flow sensor combined with the instruments’ internal pump, provide extreme flexibility for calibrating both diffusion and sample draw detection systems.
Calibration Gas Sources
50 and 100 hour sources are available.
Specifications
Chlorine Micro-Cell (Cl2) | 0.05 – 1.0 PPM |
Chlorine (Cl2) | 0.5 – 50.0 PPM |
Chlorine Dioxide (ClO2) | 0.5 – 5.0 PPM |
Hydrogen (H2) | 0.5 – 50.0 PPM |
Hydrogen Cyanide (HCN) | 0.5 – 50.0 PPM |
Hydrogen Sulfide Micro-Cell (H2S) | 0.05 – 1.0 PPM |
Hydrogen Sulfide (H2S) | 0.5 – 50.0 PPM |
PPM is variable with flow rate, output given is 0.5 LPM | |
Air Flow Rate (with internal pump) | 0.2 to 1 LPM |
Sample Draw Rate (with pump disabled) | 0.1 to 5 LPM |
Source Life | 50 or 100 hours |
Warm-up Time (to 90%) | Approx. 5 minutes |
L x W x H | 8.50 x 4.25 x 3.00″ (21.59 x 10.8 x 7.62 cm) |
Weight | 3 lb. (1360 g) |
Operating Temperature | 0° C to 50° C |
Relative Humidity (intermittent use) | 0 – 100% |
Accuracy | ±10% |
Repeatability | ±5% |
Battery Power | 4 alkaline “C” |
Battery Life | 10 hours (at .5 lpm flow rate) |
CAL 101 Calibration Gas Instrument
Gases supported:
- Low cost
- Easy to use
- Compact hand-held design.
- 2 hour generating sources.
Our Most Economical
The CAL 101 is our newest and most economical calibration gas instrument. Field replaceable calibration gas sources (generating cells) provide immediate calibration gas for Chlorine, Hydrogen Sulfide, Hydrogen and Hydrogen Cyanide.
Safe, Easy, Non-hazardous
The CAL 101 is non-hazardous to ship and will not degrade over time. The electrochemical sources are interchangeable resulting in the ability to calibrate many different types and brands of detectors with one instrument quickly, safely and easily. By simply inserting the appropriate source in the instrument, the user is ready to calibrate.
Compact
The CAL 101‘s compact size and light weight provide for safe and easy calibration even for the least accessible detection points. The two “AA” batteries powering the instrument combined with an efficient design provide the user with a light-weight instrument weighing approximately 1 pound or 0.5 Kg.
Specifications
Chlorine (Cl2) | 1.0 – 25.0 PPM |
Hydrogen (H2) | 1.0 – 25.0 PPM |
Hydrogen Sulfide (H2S) | 1.0 – 25.0 PPM |
Hydrogen Cyanide (HCN) | 1.0 – 25.0 PPM |
(output must be specified by customer upon ordering ) | |
Air Flow Rate | 0.5 or 1.0 LPM |
Replacement Source Life | 2 hours |
L x W x H | 5.00 x 3.50 x 1.50″ (12.7 x 8.9 x 3.8 cm) |
Weight | 1 lb. (454g) |
Operating Temperature | 0° C to 50° C |
Relative Humidity (intermittent use) |
0 – 100% |
Accuracy | ±10% |
Battery Power | 2 alkaline “AA” |
Battery Life | Approx. 10 hours |