Cast Iron Sluice - Slide Gates
  • Application : These are vertically sliding gates used for isolation / control of water flowing in and out of a closed conduit / orifice for seating and / or unseating water head application.
  • Standard : WWA C-560, IS-13349, BS-7775.
  • Mounting : Thimble Mounted / Wall mounted
  • Sizes (W X H) : From 100×100 mm (4"x4") up to 4000×6000 mm (160"x240")
  • Sealing : "Metal to Metal" and "Metallic to Rubber"
  • Water Head : Up to 40 m (120') seating / unseating
  • Leakage Parameter : As per AWWA / BS Standards
  • Actuation : Manual, Electric, Hydraulic & Pneumatic
Stainless Steel Sluice - Slides Gates
  • Application : These are vertically sliding gates used for isolation / control of water flowing in and out of a closed conduit / orifice for seating and / or unseating water head application.
  • Standard : AWWA C-561, BS-7775.
  • Mounting : Thimble Mounted / Wall mounted
  • Sizes (W X H) : From 100×100 mm (4"x4") up to 6000×6000 mm (240"x240")
  • Sealing : Nonmetallic
  • Water Head : Up to 50 m (150') seating / unseating
  • Leakage Parameter : As per AWWA / BS Standards
  • Actuation : Manual, Electric, Hydraulic & Pneumatic
FRP Open Channel Gates
  • Application : For isolation of flow within an open channel. Jash offers these gates completely made from Fiber Reinforced Plastic (FRP) without any carbon steel internal reinforcements eliminates two different co-efficient of thermal expansion of these different materials. These gates are good for corrosive environment / seawater application.
  • Standard : JASH
  • Mounting : Wall mounted / Channel Mounted / Channel embedded.
  • Sizes (W X H) : From 150×150 mm (6"x6") up to 2000×2000 mm (80"x80").
  • Sealing : Plastic to rubber
  • Water Head : Up to door depth seating / unseating.
  • Actuation : Manual, Electric
Aluminium Open Channel Gates
  • Application : These are vertically sliding gates used for isolation / control of water flowing in and out of a closed conduit / orifice for seating and / or unseating water head application.
  • Standard : AWWA C-562.
  • Mounting : Wall mounted / Channel mounted / Channel embedded.
  • Sizes (W X H) : From 150×150 mm (6"x6") up to 3000×5000 mm (80"x80").
  • Sealing : Nonmetallic
  • Water Head :Up to door depth seating.
  • Actuation : Manual, Electric
Cast Iron Weir Gates
  • Application : These are downward opening type gates and can be used either for Decanting of a reservoir or a tank, or For maintaining precise level control in a reservoir or a tank.
  • Standard : In compliance to AWWA C-560
  • Mounting : Wall mounted
  • Sizes (W X H) : up to 4000×6000 mm (125"x200")
  • Sealing : "Metal to Metal" and "Metallic to Nonmetallic"
  • Water Head : Up to the top of shutter / door.
  • Leakage Parameter : As per AWWA
  • Actuation : Manual, Electric
Aluminum Weir Gates
  • Application : These are downward opening type gates and can be used either for Decanting of a reservoir or a tank, or For maintaining precise level control in a reservoir or a tank.
  • Standard : In compliance to AWWA C-562
  • Mounting : Wall mounted
  • Sizes (W X H) : up to 2000×2000 mm (80"x80")
  • Sealing : Nonmetallic
  • Water Head : Up to the top of shutter / door.
  • Leakage Parameter : As per AWWA
  • Actuation : Manual, Electric
Cast Iron Flap Gates - Valves
  • Application : These are used for automatic drainage from outfall structures to rivers, estuaries and sea. These are also used for preventing reverse flow during flood from rivers /estuaries and high tide from sea. These can be offered in single or multi door design depending upon size.
  • Standard : JASH
  • Mounting : Wall mounted / Pipe flange mounted
  • Sizes (W X H) : From 150×150 mm (6"x6") up to 3000×5000 mm (125"x200") or up to 3000 mm diameter (125")
  • Sealing : Metallic / Nonmetallic
  • Water Head : Up to the top of shutter / door.
Stainless Steel Flap Gates - Valves
  • Application :These are used for automatic drainage from outfall structures to rivers, estuaries and sea. These are also used for preventing reverse flow during flood from rivers /estuaries and high tide from sea. These can be offered in single or multi door design depending upon size.
  • Standard : JASH
  • Mounting : Wall mounted / Channel mounted / Channel embedded
  • Sizes (W X H) : From 150×150 mm (6"x6") up to 3000×5000 mm (125"x200")
  • Sealing : Nonmetallic
  • Water Head : Up to 10 meters (32') seating
Aluminum Sluice - Slide Gates
  • Application : These are vertically sliding gates used for isolation / control of water flowing in and out of a closed conduit / orifice for seating and / or unseating water head application.
  • Standard : AWWA C-562.
  • Mounting : Wall mounted
  • Sizes (W X H) : From 100×100 mm (4″x4″) up to 2000×4000 mm (80″x160″)
  • Sealing : Nonmetallic
  • Water Head : Up to 5 m (15′) seating / unseating.
  • Leakage Parameter : As per AWWA
  • Actuation : Manual, Electric, Hydraulic & Pneumatic
Composite Sluice - Slide Gates
  • Application : These are vertically sliding gates used for isolation / control of water flowing in and out of a closed conduit / orifice for seating and / or unseating water head application.
  • Standard : AWWA C-563
  • Mounting : Wall mounted
  • Sizes (W X H) : From 100×100 mm (4″x4″) up to 2000×4000 mm (80″x140″)
  • Sealing : Nonmetallic
  • Water Head : Up to 10 m (30′) seating / unseating.
  • Leakage Parameter : As per AWWA
  • Actuation : Manual, Electric, Hydraulic & Pneumatic
HDPE Sluice - Slide Gates
  • Application : These are vertically sliding gates used for isolation / control of water flowing in and out of a closed conduit / orifice for seating and / or unseating water head application.
  • Standard : JASH
  • Mounting : Wall mounted
  • Sizes (W X H) : From 100×100 mm (4″x4″) up to 2000×4000 mm (80″x160″)
  • Sealing : Nonmetallic
  • Water Head : Up to 5 m (15′) seating / unseating.
  • Leakage Parameter : As per AWWA
  • Actuation : Manual, Electric, Hydraulic & Pneumatic
FRP Wall Mounted Gates
  • Application : These are vertically sliding gates used for isolation / control of water flowing in and out of a closed conduit / orifice for seating and / or unseating water head application. Jash offers these gates completely made from Fiber Reinforced Plastic (FRP) without any carbon steel internal reinforcements eliminates two different co-efficient of thermal expansion of these different materials. These gates are good for corrosive environment / seawater application.
  • Standard : In compliance to JASH
  • Mounting : Wall mounted
  • Sealing : Nonmetallic
  • Water Head : Up to 5 m (15') seating / unseating.
  • Leakage Parameter : As per AWWA
  • Actuation : Manual, Electric, Hydraulic & Pneum
Cast Iron Open Channel Gates
  • Application : These gates are embedded / wall mounted / fixed in between two parallel walls of an open channel or mounted at the end of an open channel to isolate flow within as well as out of an open channel. These are suitable for seating / unseating water head up to the height of shutter / gate / disc.
  • Standard : JASH
  • Mounting : Wall mounted / Channel mounted / Channel embedded.
  • Sizes (W X H) : From 150×150 mm (6"x6") up to 3000×5000 mm (125"x200")
  • Sealing : Metallic / Nonmetallic
  • Water Head : Up to door depth seating.
  • Actuation : Manual, Electric
HDPE Flap Gates - Valves
  • Application : These are used for automatic drainage from outfall structures to rivers, estuaries and sea. These are also used for preventing reverse flow during flood from rivers /estuaries and high tide from sea. These can be offered in single or multi door design depending upon size.
  • Standard : JASH
  • Mounting : Wall mounted
  • Sizes (W X H) : From 150×150 mm (6"x6") up to 5000×5000 mm (200"x200")
  • Sealing : Nonmetallic
  • Water Head : Up to 10 meters (32') seating
HDPE Open Channel Gates
  • Application : These are vertically sliding gates used for isolation / control of water flowing in and out of a closed conduit / orifice for seating and / or unseating water head application.
  • Standard : AWWA C-563.
  • Mounting : Wall mounted.
  • Sizes (W X H) : From 150×150 mm (6"x6") up to 3000×3000 mm (120"x120").
  • Sealing : Nonmetallic
  • Water Head : Up to door depth seating.
  • Actuation : Manual, Electric
Stainless Steel Channel Gates
  • Application : These gates are embedded / wall mounted / fixed in between two parallel walls of an open channel or mounted at the end of an open channel to isolate flow within as well as out of an open channel. These are suitable for seating / unseating water head up to the height of shutter / gate / disc.
  • Standard : AWWA C-513.
  • Mounting : Wall mounted / Channel mounted / Channel embedded.
  • Sizes (W X H) : From 150×150 mm (6"x6") up to 3000×5000 mm (125"x200")
  • Sealing : Nonmetallic
  • Water Head : Up to door depth seating.
  • Actuation : Manual, Electric
Stainless Steel Weir Gates
  • Application : These are downward opening type gates and can be used either for Decanting of a reservoir or a tank, or For maintaining precise level control in a reservoir or a tank.
  • Standard : In compliance to AWWA C-561
  • Mounting : Wall mounted
  • Sizes (W X H) : up to 4000×6000 mm (125"x200")
  • Sealing : Nonmetallic
  • Water Head : Up to the top of shutter / door.
  • Leakage Parameter : As per AWWA
  • Actuation : Manual, Electric
Aluminum Extruded Stop Logs
  • Application : Stop logs are used for isolation duties in open channel. Stoplogs can be of single piece stacked together to achieve the desired total height.
  • Standard : JASH
  • Mounting : Wall mounted / Channel mounted / Channel embedded.
  • Sizes (W X H) : From 150×150 mm (6"x6") up to 3000×5000 mm (125"x200")
  • Sealing : Nonmetallic
  • Water Head : Up to logs stacked height seating / unseating.
Composite Stop Logs
  • Application : Stop logs are used for isolation duties in open channel. Stoplogs can be of single piece stacked together to achieve the desired total height.
  • Standard : JASH
  • Mounting : Wall mounted / Channel mounted / Channel embedded.
  • Sizes (W X H) : From 150×150 mm (6"x6") up to 3000×5000 mm (125"x200")
  • Sealing : Nonmetallic
  • Water Head : Up to logs stacked height seating / unseating.
Stainless Steel Fabricate Stop Logs
  • Application : Stop logs are used for isolation duties in open channel. Stoplogs can be of single piece stacked together to achieve the desired total height.
  • Standard : JASH
  • Mounting : Wall mounted / Channel mounted / Channel embedded.
  • Sizes (W X H) : From 150×150 mm (6"x6") up to 3000×5000 mm (125"x200")
  • Sealing : Nonmetallic
  • Water Head : Up to logs stacked height seating / unseating.