HVAC Products

BETEC CAD. has been leader for over 20 years, in designing, manufacturing, durable, high performance control Dampers for industrial and commercial building ventilation applications. Constructed from heavy-duty, high quality steel with the most advanced equipments in the industry. BETEC CAD. dampers can stand up to the toughest and most demanding environments and can be custom-built to meet the exact needs of virtually any ventilation or process applications. BETEC CAD. manufactures, UL classified dampers to meet the standards of NFPA - National Fire Protection Authority,for human life and property safety.

To meet the demands of fire and smoke protection, these dampers are available in a wide range of classifications and with a variety of custom built features and options. BETEC CAD. fire dampers are designed to operate as an integral part of Engineered smoke management system for building controls, and are used in walls, ceiling and floors. They are suitable for both dynamic or static fan on systems.

Fire Dampers are required by the International Uniform Building Code to maintain the required fire resistance rating of walls, partitions and floors when they are penetrated by air ducts or other ventilation openings. A duct or ventilation openings in any of the fire rated partitions would permit a fire to spread from the compartment of origin to adjoining compartments or space.

Fire Dampers or Fire-Smoke dampers are installed in these ducts or venti- lation openings. They close automatically upon detection of heat by a Thermal responsive device (TRD), blocking the openings and preventing the spread of fire or smoke in to the adjoining compartment. BETEC CAO’s experienced and professional team provide quality products through continuous commitment to research and development and the introduction of new technologies.

Fire-resistive construction requirements usually are determined by the local or state code authority. Local and state codes are usually adaptations of the national and model codes, such as the International Building Code, published by the International Code Council, Inc. (ICC); BOCA National Building Code published by the Building Officials and Code Administrators International, Inc. (BOCA); the Uniform Building Code published by the International Conference of Building Officials (ICBO); and the Standard Building Code published by the Southern Building Code Congress International, Inc. (SBCCI).

The National Fire Codes published by the National Fire Protection Association (NFPA) contain recommended practices and technical data for determining fire-resistive requirements. Standards for fire-resistive tests may be found through the American National Standards Institute (ANSI), ASTM, UL, and the NFPA. Testing of fire-resistive components and assemblies may be conducted by any of several independent testing laboratories. The most prominent testing laboratories evaluating fire resistive materials and assemblies are UL - Under Writers Laboratories of USA.


Motorized Fire Damper

Read More

Motorized Fire Damper(DTRD)

Read More

Fire Damper

Read More


Motorized Smoke Damper

Read More

Motorized Fire Smoke Damper

Read More

Tunnel Ventilation Damper

Read More

Oil & Gas Damper

Read More

Coast Guard Fire Damper

Read More

Volume Control Damper

Read More

Round Volume control Dampers

Read More

Motorized Volume control Dampers

Read More

Variable Air Volume - By Pass

Read More

Variable Air Volume - Pressure Dependent

Read More

Variable Air Volume - Pressure Independent

Read More

Variable Air Volume - Induction VAV

Read More

Constant Air Volume

Read More

Sound Attenuator

Read More

Sound Attenuators - Cylindrical Type

Read More

Jet Fans

Read More

Weather Louver

Read More

Sand Trap Louver

Read More

Acoustic Louver

Read More

Sunshade Louver

Read More

Plenums

Read More

Variable Plenums

Read More

Fire Rated Doors - FRD

Read More

Access Doors

Read More

Duct Heaters - DH

Read More

Duct Heaters - DH

Read More

VAV with Duct Heater

Read More

Metallic Filters - BF 1

Read More

Synthetic Filters - BF 2

Read More

Bag Filters - BF 3

Read More

Fire Rated Steel Doors and Frames

Read More

Betectemet Blast Door So-3

Read More

Betectemet Double Blast Door So-3

Read More

Blast Damper HV

Read More